The Nobles of Global Trade

YH-725 Bi-Level Ventilator

Aproved: FDA + CE Bi-level device is indicated for treatment of sleep apnea hypopnea syndrome in patients weighing more than 66lb (30kg). It is intended both for home use and hospital use. The humidifier is intended for single patient use in the home environment and re-use in a hospital/institutional environment
SKU: VE1027OX08
$8,844.44
excluding shipping
This product has a minimum quantity of 100

Medical Ventilator YH-725
Package: 2 cartons
Size: 48.5×32.5×21.5cm, 80x45x30cm
N.W.: 20KGS
G.W.: 23KGS

1. Scope of application:
For adult patients with ARDS, hypoventilation syndrome, for
bi level non invasive
ventilation in a hospital or home.
2 .
the main function:
1. Different tre atment options can b e prov i ded according to patients' needs, from CPAP
to S, T, S / T, VGPS five modes 。
2. Adjustable trigger sensitivity.
3. Realtime monitoring and recordi ng of blood oxygen saturation.
4.alarm function.
5. Record function (SD card).
6. Maximum leak compensation function. 60L/min
7. With trolley, easy to move in the hospital
3.the key technical parameters:
1. Working mode: CPAP, S, T, ST, VGPS.
2. Ventilation parameters:
2.1 Inspiratory pressure: 4
25 cmH2O (0.5 cmH2O interval)
2.2 Expiratory pressure: 4 25 cmH2 O (0.5 cmH2 O interval)
2.3 Treatment pressure: 4 20 cmH2O (in CPAP mode, 0.5 cmH2O interval)
2.4 Delayed boost: 0
45 minutes (interval of 5 minutes)
2.5 Breathing frequency: 5
50 times / minute (interval 1 time / minute)
2.6 Breathing rati
o: 10 70% (interv al of 1%)
2
2.7 Rise time: 1.7 Rise time: 1--5 steps (1 s5 steps (1 sttep intep inteerval, 1 step rises fastest, 5 steps rises most slowly)rval, 1 step rises fastest, 5 steps rises most slowly)
2.8 Inhalation sensitivity: 1
2.8 Inhalation sensitivity: 1--5 steps (1 step interval, 1st step triggers fastest, 5th step 1st 5 steps (1 step interval, 1st step triggers fastest, 5th step 1st step triggers slowest)step triggers slowest)
2.9 Exhalation sen
2.9 Exhalation sensitivity: 1sitivity: 1--5 (1 5 (1 interval, tinterval, the 1st trigger is the fasteshe 1st trigger is the fastestt, 5th , 5th aand 1st the nd 1st the slowest)slowest)
2.10 Tidal volume: 50
2.10 Tidal volume: 50--1500ml (effective in VGPS mode, interval 50ml)1500ml (effective in VGPS mode, interval 50ml)、、
3.
3.VGPSVGPS((ssame with AVAPSame with AVAPS,,can set can set Target tidal volumeTarget tidal volume))mmodeode::
3.1 Maximum IPAP va
3.1 Maximum IPAP value adjustable range: 4lue adjustable range: 4--2525 cmH2OcmH2O
3.2 Adjustable range of minimum IPAP value: 4
3.2 Adjustable range of minimum IPAP value: 4--2525 cmH2OcmH2O
3.3 EPAP value adjustable range: 4
3.3 EPAP value adjustable range: 4--2525 cmH2OcmH2O
3.4 Target Tidal Volume: 50
3.4 Target Tidal Volume: 50--1500ml1500ml
4. Display
4. Display range of monitoring setting range of monitoring setting parameters:parameters:
4.1 Respiratory waveform can be displayed;
4.1 Respiratory waveform can be displayed;
4.2 Current mode: CPAP, S, T, ST, VGPS
4.2 Current mode: CPAP, S, T, ST, VGPS
4.3 Inspiratory pressure: 4
4.3 Inspiratory pressure: 4--2525 cmH2OcmH2O
4.4 Expiratory press
4.4 Expiratory pressure: 4ure: 4--2525 cmH2OcmH2O
4.5 Breathing frequency: 5
4.5 Breathing frequency: 5--50 times / minute50 times / minute
4.6 Breathing ra
4.6 Breathing ratio: 10tio: 10--70%70%
4.7 Air leakage:
4.7 Air leakage: 2020--99.9lpm99.9lpm
4.8 Tidal volume: 50
4.8 Tidal volume: 50--1500ml1500ml
4.9 minute ventilation: 0
4.9 minute ventilation: 0--50lpm50lpm
4.10 Blood oxygen saturation: 70
4.10 Blood oxygen saturation: 70--100%100%
4.11 Pulse rate: 25
4.11 Pulse rate: 25--250bpm250bpm
4.12 Delay boost: 0
4.12 Delay boost: 0--45 minutes45 minutes
5. Alarm items:
5. Alarm items:
5.1 High pressure sound prompt: Turn on / off sound prompt
5.1 High pressure sound prompt: Turn on / off sound prompt
5.2 Low minut
5.2 Low minute ventilation sound prompt: Turn on / off sound prompt, can be set to e ventilation sound prompt: Turn on / off sound prompt, can be set to 11--10L (interval 1L)10L (interval 1L)
5.3 Air leakage sound prompt: on / off
5.3 Air leakage sound prompt: on / off
5.4 Power off sound prompt: on / off
5.4 Power off sound prompt: on / off
5.5 Choking voice
5.5 Choking voice prompt: On / off, choking time can be set to 10prompt: On / off, choking time can be set to 10--40 seconds (interval 40 seconds (interval of of 5 seconds)5 seconds)
5.6 Low Tidal Volume Sound Prompt: On / Off, Set Tidal Volume Value Range 50
5.6 Low Tidal Volume Sound Prompt: On / Off, Set Tidal Volume Value Range 50--500ml 500ml ((Interval 50ml))((Interval 50ml))
6.Specifications
6.Specifications
6
6.1 .1 TotalTotal Weight: about Weight: about 2200kg ikg including the trolley ncluding the trolley aand the devicend the device
6.2 Operating temperature: 5
6.2 Operating temperature: 5--35 ° C35 ° C
6.3 Relative humidity: 10%
6.3 Relative humidity: 10% --90%90%
6.4 Power supply: input is AC 100
6.4 Power supply: input is AC 100--240V, 50240V, 50--60Hz, 1.8A Max; output: DC 24V, 3.33A.60Hz, 1.8A Max; output: DC 24V, 3.33A.